glosat card splitter
 

Download:-

 click here to download  IMAGE30b  firmware ( the newest firmware to V2 and V3 )
 
This page is contain the firmware for the V2 and V3 GloSAT Card Splitter but not all the V2 can be upgrade or change the systems, the old units is not upgradeable  ( contact GloSAT.com for more information ).
their are two types of the update :-
1- TE :- 1 system only.
2- T0 :- 4in1 system which is included with 4 systems in the same time.
note:- also you can not change from one system to other unless you had other system slaves or 5in1 slaves.
how to do it:-
 
 

smart mouse

 
 
  •  insert the slaves inside the smart mouse.
  • connect the slaves to the masters by the port 0
  • the ports of the masters units:-
  • CSP4RO  [v2] :-
    P 01 23
    CS8PRO  [v2.2] (black connector) :-
  •      -- -- -- --
    P 01 23 45 67

    CS8PRO  [v2.1] :-

  • P 01 23 45 67

  • CSP16 RO [v2] :-

  •     13 57 9B DF
    P
    02 46 8A CE
  • Run the software.
picture 1 :-
 
1- first change the connect port by F1 with the smart mouse frequency
1- first change the connect port by F1 with the smart mouse frequency
2- change the slaves type ( system ) by F2 ,
 TE :- 1 system only.
T0 :- 4in1 system
3- change the device that you want to update by  F8
4- you must erase device firmware by the F6 key.
5- if you want to erase the slaves ATR in the salves used the F4 key.
 
picture 2 :-
 
you will ask to remove the power from the target and apply power again , after that you need to press any key to get the normal screen and after that you press F7 key to start download the firmware to the target device , you will get update information in the screen like this:-
 
picture 3 :-
 
 and after that you will get this screen and that mean the firmware is update
picture 3 :-

V3 wireless firmware update:-

to update the wireless master, you must used  Special loader code (SWID 0491) is loaded to slave B/C via jumper method (use tx.bat in extras folder to get this SWID).

how to load the

Put slave in SM reader.
run
tx.bat in extars folder and choice
odd parity with key F2.
Select target slave with key F8. Select one of these:
- v3 Slave A (T=0)
- v3 Slave A (T=E)
- v3 Slave B
 (SWID 0491) [this also works for slave C]

Press F7.
While response is locked (SM - 0, PX - 0 etc.) short the two pins shown on photo (just hold some wire there, don't solder). Code will start loading.
 

picture:- short the two pins with wire to load the slaves firmware easily

Erase the master firmware:- insert the slave with special loader  (SWID 0491) inside the master to erase the master firmware

load the master firmware :- after erase the master firmware by the slave, Put slave ( with special loader  (SWID 0491 ) in Smart mouse reader

insert the card inside the master

Run term_gui.exe
Select odd parity with key F2.
Settings: odd parity, target v3 master, press key F7.
If response is locked (60 60 60....) then exit term_gui.exe and start it again.
Then re-insert card in master (or power plug) and press F7 again.
Code download always starts on this 2nd attempt.

 load the slave firmware : THE JUMPER METHOD:

There is an easy way to load code to slave A/B/C without using scripts.


Put slave in SM reader.
Run term_gui.exe.
Select odd parity with key F2.
Select target slave with key F8. Select one of these:
- v3 Slave A (T=0)
- v3 Slave A (T=E)
- v3 Slave B [this also works for slave C]
 

( when you choice slave B or A , the SWID must be 04F4  or other new SWID   for the last firmware, if you get ( SWID 0491 ) by term_gui.exe  delete the folder and extract form the zip file ( IMAGE30b.zip )

 
Press F7.
While response is locked (SM - 0, PX - 0 etc.) short the two pins shown on photo (just hold some wire there, don't solder).
Code will start loading.

 



 

 

 


card splitter CSPRO4 GloSat SplitterPRO  CSPRO8 CS8PRO CS4PRO CS16PRO nova , showtime , ART ,multichoice DSTV CSPRO16 2 ,Viaccess2 ,  SECA2 , ,   ,  , Viaccess Seca Mediaguard , DNS sharing , Viaccess, Conax, Cryptoworks, Nagravision, , SECA 